Mostrar el registro sencillo del ítem

dc.contributorInstituto de Medio Ambiente, Recursos Naturales y Biodiversidad de la Universidad de Léones_ES
dc.contributor.authorSan Martin Bécares, María Isabel 
dc.contributor.authorMateos González, Raúl 
dc.contributor.authorEscapa González, Adrián 
dc.contributor.authorMorán Palao, Antonio 
dc.contributor.otherIngenieria Quimicaes_ES
dc.date2019-02-11
dc.date.accessioned2019-02-11T16:16:47Z
dc.date.available2019-02-11T16:16:47Z
dc.date.issued2019-02-11
dc.identifier.citationJournal of Environmental Science and Health, Part Aes_ES
dc.identifier.urihttp://hdl.handle.net/10612/9569
dc.description9 p.es_ES
dc.description.abstractThis study was aimed at understanding the effect of applied voltage, catholyte and reactor scale on nitrogen recovery from two different organic wastes (digestate and pig slurry) by means of microbial electrolysis cell (MEC) technology. For this purpose, MEC sizes of 100, 500 and 1000 mL were tested at applied voltages of 0.6, 1 and 1.4 V using either a phosphate-buffered solution or NaCl solution as the catholyte. By increasing the reactor size from 500 mL to 1000 mL, a decrease in the ammonia recovery efficiency from 47 to 42 % was observed. The results also showed that the phosphate-buffered solution is preferable as the catholyte and that the voltage applied does not have a noticeable effect on current production and ammonia recovery. Low biodegradability of the wastes was identified as the main bottleneck. This research was supported by the European Union Horizon 2020 Research and Innovation Programme (GA nº 668128-Newfert-H2020-BBI-PPP-2014-1). Financing: This project has received funding from the Bio Based Industries Joint Undertaking under the European Union’s Horizon 2020 research and innovation programme under grant agreement No 668128es_ES
dc.languageenges_ES
dc.publisherTaylor & Francises_ES
dc.subjectIngeniería químicaes_ES
dc.subject.otherIngeniería Ambientales_ES
dc.subject.otherBioprocesoses_ES
dc.subject.otherIngeniería Eléctricaes_ES
dc.subject.otherMicrobial electrolysis celles_ES
dc.subject.otherAmmonia recoveryes_ES
dc.subject.otherHigh nitrogen concentration wastewateres_ES
dc.subject.otherScaling upes_ES
dc.titleUnderstanding nitrogen recovery from wastewater with a high nitrogen concentration using microbial electrolysis cellses_ES
dc.typeinfo:eu-repo/semantics/preprintes_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem