Mostrar el registro sencillo del ítem
dc.contributor | Escuela Superior y Tecnica de Ingenieros de Minas | es_ES |
dc.contributor.author | Fraile Fernández, Fernando Jorge | |
dc.contributor.author | Martínez García, Rebeca | |
dc.contributor.author | Jagadesh, P | |
dc.contributor.author | Búrdalo Salcedo, Gabriel | |
dc.contributor.author | Palencia Coto, María Covadonga | |
dc.contributor.author | Fernández Raga, María | |
dc.contributor.other | Ingenieria Mecanica | es_ES |
dc.date | 2021 | |
dc.date.accessioned | 2024-05-03T07:07:53Z | |
dc.date.available | 2024-05-03T07:07:53Z | |
dc.identifier.citation | Martínez-García, R.; Jagadesh, P.; Búrdalo-Salcedo, G.; Palencia, C.; Fernández-Raga, M.; Fraile-Fernández, F.J. Impact of Design Parameters on the Ratio of Compressive to Split Tensile Strength of Self-Compacting Concrete with Recycled Aggregate. Materials 2021, 14, 3480. | es_ES |
dc.identifier.uri | https://hdl.handle.net/10612/20287 | |
dc.description.abstract | [EN] Most concrete studies are concentrated on mechanical properties especially strength properties either directly or indirectly (fresh and durability properties). Hence, the ratio of split tensile strength to compressive strength plays a vital role in defining the concrete properties. In this review, the impact of design parameters on the strength ratio of various grades of Self-Compacting Concrete (SCC) with recycled aggregate is assessed. The design parameters considered for the study are Water to Cement (W/C) ratio, Water to Binder (W/B) ratio, Total Aggregates to Cement (TA/C) ratio, Fine Aggregate to Coarse Aggregate (FA/CA) ratio, Water to Solid (W/S) ratio in percentage, superplasticizer (SP) content (kg/cu.m), replacement percentage of recycled coarse aggregates (RCA), replacement percentage of recycled fine aggregates (RFA), fresh density and loading area of the specimen. It is observed that the strength ratio of SCC with recycled aggregates is affected by design parameters. | es_ES |
dc.language | eng | es_ES |
dc.publisher | MDPI | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería de minas | es_ES |
dc.subject.other | Strength Ratio | es_ES |
dc.subject.other | Self-compacting Concrete | es_ES |
dc.subject.other | Recycled Aggregates | es_ES |
dc.subject.other | Design Parameters | es_ES |
dc.title | Impact of Design Parameters on the Ratio of Compressive to Split Tensile Strength of Self-Compacting Concrete with Recycled Aggregate | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.identifier.doi | 10.3390/MA14133480 | |
dc.description.peerreviewed | SI | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.identifier.essn | 1996-1944 | |
dc.journal.title | Materials | es_ES |
dc.volume.number | 14 | es_ES |
dc.issue.number | 13 | es_ES |
dc.page.initial | 3480 | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es_ES |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos [5509]