dc.contributor | Facultad de Ciencias de la Actividad Fisica y del Deporte | es_ES |
dc.contributor.author | Jiménez Pérez, Irene | |
dc.contributor.author | Gil Calvo, Marina | |
dc.contributor.author | Pérez Soriano, Pedro | |
dc.contributor.author | Priego Quesada, Jose Ignacio | |
dc.contributor.author | Lucas Cuevas, Angel G | |
dc.contributor.other | Educacion Fisica y Deportiva | es_ES |
dc.date | 2020 | |
dc.date.accessioned | 2024-04-25T07:52:31Z | |
dc.date.available | 2024-04-25T07:52:31Z | |
dc.identifier.citation | Gil-Calvo M, Jimenez-Perez I, Priego- Quesada JI, Lucas-Cuevas A´G, Pe´rez-Soriano P (2020) Effect of custom-made and prefabricated foot orthoses on kinematic parameters during an intense prolonged run. PLoS ONE 15(3): e0230877. | es_ES |
dc.identifier.uri | https://hdl.handle.net/10612/20086 | |
dc.description.abstract | [EN] Foot orthoses are one of the most used strategies by healthy runners in injury prevention
and performance improvement. However, their effect on running kinematics throughout an
intense prolonged run in this population is unknown. Moreover, there is some controversy
regarding the use of custom-made versus prefabricated foot orthoses. This study analysed
the effect of different foot orthoses (custom-made, prefabricated and a control condition) on
spatio-temporal and angular (knee flexion and foot eversion) kinematic parameters and
their behaviour during an intense prolonged run. Twenty-four recreational runners per-
formed three similar tests that consisted of running 20 min on a treadmill at 80% of their
maximal aerobic speed, each one with a different foot orthosis condition. Contact and flight
time, and stride length and stride rate were measured every 5 min by an optical measure-
ment photoelectric cell system. Knee flexion and foot eversion kinematic parameters were
measured by two high-speed cameras. No significant differences were found between the
different foot orthoses in any of the time points studied and between the interaction of foot
orthosis and behaviour over time, in any of the variables studied (P > 0.05). The use of cus-
tom-made and prefabricated foot orthoses during an intense prolonged run does not pro-
duce changes in spatio-temporal and kinematic parameters in healthy runners. These
results suggest that a healthy runner maintains its ideal movement pattern throughout a 20
minute prolonged run, regardless the type of foot orthosis used | es_ES |
dc.language | eng | es_ES |
dc.publisher | Public Library of Science | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Educación Física | es_ES |
dc.subject.other | Kinematic parameters | es_ES |
dc.title | Effect of custom-made and prefabricated foot orthoses on kinematic parameters during an intense prolonged run | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.identifier.doi | 10.1371/JOURNAL.PONE.0230877 | |
dc.description.peerreviewed | SI | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.identifier.essn | 1932-6203 | |
dc.journal.title | PLOS ONE | es_ES |
dc.volume.number | 15 | es_ES |
dc.issue.number | 3 | es_ES |
dc.page.initial | e0230877 | es_ES |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.project | The work of IJP was supported by the Spanish Government (Ministerio de Ciencia, Innovacio´n y Universidades, Grant FPU14//05626). In addition, the research project was supported by the Spanish Government (Ministerio de Economı´a y Competitividad, Subdireccio´n General de Proyectos de Investigacio´n. Convocatoria Proyectos I+D “Excelencia”, Subprograma de Generacio´n de Conocimiento, 2013 (project DEP2013-48420-P)). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. | es_ES |